Hydrogen Sulphide Reduction

Signs of the problem – A smell of sulphur (like rotten eggs) from the water.

Solution. There are several approaches depending on the severity of the hydrogen sulphide. The water needs to be aerated. Once oxidation has taken place the water is passed through a reduction media such as Filox or Catalytic Carbon. For very high levels of hydrogen sulphide a tank and blower system with exhaust can be used or contact assembly followed by Filox vessel. Filox media has a long lifespan (5+ years) in comparison to Catalytic Carbon (1-2 years).

Hydrogen sulphide reduction